WB-MWAC v.2 firmware changelog
Overview
Device firmware can be updated over Modbus; see the instructions.
This page lists changes since the beginning of 2022. Earlier changes are in Firmware Changelog.
Changelog
1.27.0 (30.09.2026) — available in testing
- Added water-flow influence setting for anti-seize protection scheduling.
- Added anti-seize protection statuses indicating postponement reasons.
1.26.2 (21.08.2026)
- LED state synchronized with input level when input mode changes.
- Fixed false front-panel button activation at firmware startup.
1.26.1 (07.08.2026)
1.26.0 (13.07.2026)
- Added service coil register 65500 for LED testing.
1.25.1 (03.07.2026)
- Fixed Modbus issues:
- Improved Fast Modbus arbitration timing stability.
- ERRMODBUS008: Unexpected behaviour with long request frames
- ERRMODBUS009: Unexpected behaviour when reading near address 0xFFFF in continuous-reading mode
- ERRMODBUS010: Incorrect request validation and handling of invalid requests
- ERRMODBUS011: Incorrect handling of invalid Fast Modbus event-configuration requests
1.25.0 (08.06.2026)
- Added register for audible leak-alarm duration.
1.24.1 (03.06.2026)
- ERRMODBUS007: Fixed event loss when two devices transmit events simultaneously on the same bus.
- Restored event generation when Reset Leak mode is pressed.
- Fixed false leak actions on a long press in edge-control input mode.
1.24.0 (05.05.2026)
- Added valve anti-seize protection (WB-MWAC v.2 only)
- Added remaining wet-cleaning time register.
- Improved reliability during power loss.
- Optimised filesystem operation.
- Added FlashFS diagnostic service registers.
- Optimized stack usage when requesting many registers.
1.23.0 (22.12.2025)
- Added stack and RAM monitoring service registers
- Added a service register for the last MCU reset cause
- Added a firmware update counter service register
- Added FlashFS diagnostic service registers
- Added device batch-number register (WB-MWAC v.2 only)
- Improved MCU supply voltage measurement accuracy on new devices
1.22.1 (03.10.2025)
- Fixed configuration migration when upgrading to firmware 1.22.0 — ERRMWAC2009
1.22.0 (22.09.2025)
- Added indication when a leak sensor has dried
- Added an audible notification after leaving Leak mode
- Added NO/NC leak-sensor selection
- Added a register to restore default settings
For WB-MWAC v.2:
- Added buzzer control through inputs, a register and Safety Mode
1.21.7 (26.05.2025)
- Removed the ability to enable Leak mode through a Modbus register on WB-MWAC v.2 ERRMWAC2008
1.21.6 (31.03.2025)
- Fixed relay state on first power-on of WB-MWAC v.2 ERRMWAC2007
- Added microcontroller UID Modbus registers for WB-MWAC v.2
- Fixed unexpected behaviour when invalid values are written to some registers ERRMODBUS003
- Fixed loss of Modbus response under very frequent requests (observed on WB-MAP12E)
1.21.5 (13.03.2025)
- Fixed critical firmware and bootloader errors that could prevent startup after power cycling: ERRBOOT004, ERRMWAC2006
1.21.4 (11.11.2024)
- Added parity checking for received Modbus data ERRMODBUS006
1.21.3 (14.08.2024)
For WB-MWAC:
- Removed complementary-mode selection for noncomplementary inputs,
- Turn all relays off on press input mode no longer disables wet-cleaning mode,
- Status LED operation.
For WB-MWAC v.2:
- Fixed inability to set RS-485 parity other than N ERRMWAC2003,
- Fixed incorrect microcontroller temperature and supply-voltage measurements ERRMWAC2004,
- Fixed ability to select nonexistent modes 0–2 in registers 9–14 ERRMWAC2005.
1.21.2 (17.05.2024)
- Added minimum microcontroller-voltage register
For WB-MWAC:
- Restored Alarm output switching in mapping-matrix settings
1.21.1 (03.04.2024)
- Improved wet-cleaning mode visual indication
- Prevented Leak mode activation while Wet cleaning mode is active
- Prevented setting Wet cleaning timer to 0
- Fixed persistence of Wet cleaning timer after restart
- Fixed replies to address 0xFD packets that did not contain Fast Modbus commands ERRMODBUS001
For WB-MWAC:
- Added sensor-state checking when leaving Wet cleaning mode
- Fixed default input-to-output control settings
For WB-MWAC v.2:
- Fixed persistence of Restore valve state after leak is resolved after restart
- Significantly accelerated K1 and K2 button processing
- Fixed counter configuration persistence after restart: Pulse weight P1/P2 and Initial counter value P1/P2
- Added range checking for Pulse weight P1 and P2 registers
1.21.0 (25.01.2024)
Separate firmware branch for WB-MWAC and WB-MWAC v.2.
- Fixed the Repeat after 20 minutes if input is still active function, which did not work
- Leak sensors are now checked at startup. Previously no alarm occurred if the sensor was triggered before the device powered on
- Added Wet cleaning mode to suspend leak-sensor response while cleaning
- Added fail-safe alarm-output behavior settings
- Allowed leak-sensor processing in Safety Mode
- Added configuration-reset register
- Added speaker-disable register
- Added WB-MWAC v.2 support
1.20.4 (07.11.2023)
1.20.3 (11.09.2023)
1.20.1 (24.07.2023)
1.20.0 (11.05.2023)
1.19.2 (05.12.2022)
1.19.1 (16.11.2022)
1.19.0 (11.11.2022)
1.18.5 (01.07.2022)
1.18.4 (30.05.2022)
1.18.2 — 1.18.3
1.18.0 — 1.18.1
1.17.8 (21.04.2022)
1.17.7 (30.03.2022)
1.17.6 (30.03.2022)
1.17.5 (05.03.2022)
1.17.3 — 1.17.4
1.17.2 (31.01.2022)
1.17.1